LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 1995 >> Montero SR, V4AW2 >> Repair and Diagnosis >> Engine Performance >> Sensor Range Charts >> Engine Controls - Sensor Operating Range Charts - 3.5L >> Sensor Operating Range Charts >> Notes

Sensor Operating Range Charts: Notes

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance. For connector and terminal identification, see WIRING DIAGRAMS  section.
AIRFLOW METER HERTZ TEST (1)

Condition Hz
DOHC (California)
700 RPM 27-53
2000 RPM 60-100
DOHC (Federal)
700 RPM 29-55
2000 60-100
2500 91-131
(1) Measure hertz frequency with Multi-Use Tester (MUT-II).
COOLANT TEMPERATURE SENSOR RESISTANCE

Application & Temperature °F (°C) Ohms
32 (0) 5800
68 (20) 2400
104 (40) 1100
176 (80) 300
INTAKE AIR TEMPERATURE SENSOR RESISTANCE

Application & Temperature °F (°C) Ohms
32 (0) 6000
68 (20) 2700
176 (80) 400
OXYGEN SENSOR VOLTAGE TEST (1)

Application Volts
Lean 0.6
Rich 1.0
(1) Test at normal operating temperature.