No Load Tests

Connect starter in series with a 12-volt battery, a voltmeter and a 1000-amp ammeter. Compare readings with STARTER NO LOAD SPECIFICATIONS .

STARTER NO LOAD SPECIFICATIONS (1)

Application Max. Amps Min. RPM
Cordia, Precis & Tredia (2) 60 6500
Galant & Mirage
Manual Transmission 60 6600
Automatic Transmission 60 6600
Montero 90 3000
Pickup
Manual Transmission 60 6500
Automatic Transmission 100 3000
Starion Turbo 100 3000
(1) Applied voltage of 11.5-12 volts.