Calibration Of Consumption Indicator: Application
Caution: Before application of the adjustment, ensure that there are no faults in the DME control module or other complaints regarding engine operation.
Calibration can be used if the customer determines and complains about a deviation between the following values:
- Fuel consumption calculated by the on-board computer
- Fuel consumption determined on the basis of refueling
These two values must be entered at the corresponding point during the calibration procedure.
The calibration function then automatically calculates the correct correction factor and transfers it to the DME control module.
The correction factor can decrease or increase by a maximum of 12 %. If the newly calculated correction factor is outside these limits, the user will be given the option of setting the factor to the maximum permissible limit or not at all.