LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2017 >> Cooper Base, 2D Convertible, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 89 (General Electrical System - Repair -- F55) >> Plug Connections, Terminals >> 61 13... Socket housing 42-, 43-, 46-pin, Hybrid System MQS/MPQ

61 13... Socket housing 42-, 43-, 46-pin, Hybrid System MQS/MPQ

WARNING: This page is about a different variant/trim than selected.

Special tools required: 

Manufactured by AMP:  The following bushing housings without single conductor seal can be fitted in the socket housings:

Open secondary locks (1) on socket housing.

Press back safety catch of MQS contacts (2) with special tool 61 0 312 (61 1 134) and pull out cable with contact.

Press back safety catch of MPQ contacts (3) with screwdriver and pull out cable with contact.

Fig 1: Opening Secondary Locks On Socket Housing
G05478537Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

Bend open safety catch of contacts gently before inserting into connector housing.

For installation of contacts, observe chamber numbers on reverse side of socket housing.

Fig 2: Chamber Numbers On Reverse Side Of Socket Housing
G05478538Courtesy of BMW OF NORTH AMERICA, INC.