Home >> Mini >> 2013 >> Cooper Base, 2D Convertible, Standard Trans >> Repair and Diagnosis >> General Information >> OEM General Information >> Functional Description -- R57 >> IHKA (Integrated Automatic Heating/Air Conditioning System) >> Notes for Service Technicians >> Running in the air-conditioning compressor

Running in the air-conditioning compressor

IMPORTANT: After replacement, allow the air-conditioning compressor to run in.

After replacement of the air-conditioning compressor or refilling the refrigerant circuit, the air-conditioning compressor must be run in. Running in is required to ensure lubrication (oil distribution). Running in can only be carried out using the BMW diagnosis system.

For this running in, the air-conditioning compressor must be operated within the specified engine speed range. Here, the oil volume filled by the manufacturer mixes evenly with the liquid refrigerant.

IMPORTANT: Do not exceed the specified engine speed.

If the engine speed exceeds the specified engine speed range, running in is aborted automatically. The running-in procedure must then be repeated in its entirety.