Home >> Mini >> 2012 >> Cooper Base, 2D Convertible, Automatic Trans >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Memory Modules >> General Electrical System - Repair (R58 & R59) -- Cooper >> Plug Connections, Terminals, Power Distribution Box >> 61 13... Opening plug housings and removing contacts of different plug systems >> 61 13... Control unit plugs, 25-, 35-, 55-, 83-, 88-pin

61 13... Control unit plugs, 25-, 35-, 55-, 83-, 88-pin

Special tools required: 

Release screws (1).

Lever out pin sensor (2) with gasket (3) in direction of arrow.

Fig 1: Removing Pin Sensor With Gasket
G08509612Courtesy of BMW OF NORTH AMERICA, INC.

Remove gasket (3).

Pull out housing lock (4) in direction of arrow and unlock.

Fig 2: Pulling Out Housing Lock
G08509613Courtesy of BMW OF NORTH AMERICA, INC.

Press down retaining hook (5) of corresponding contact and pull out cable with contact.

Required special tool for mini flat spring contacts 61 0 312

Required special tool for mini flat spring contacts 61 0 314

Fig 3: Pressing Down Retaining Hook
G08509614Courtesy of BMW OF NORTH AMERICA, INC.

Special tool 61 0 315 for double flat spring contacts (dual retaining hooks).

Fig 4: Identifying Double Flat Spring Contacts (Dual Retaining Hooks)
G08509615Courtesy of BMW OF NORTH AMERICA, INC.

Special tool 61 0 323 for double flat spring contacts (special retaining hook).

Fig 5: Identifying Double Flat Spring Contacts (Special Retaining Hook)
G08509616Courtesy of BMW OF NORTH AMERICA, INC.