Notes for Service department
It is necessary when handling an AGM battery to observe some particular points pertaining to battery changing and installation location.
Charging
When charging removed batteries (so-called stand alone batteries), do not exceed the maximum charging voltage of 15.2 V at room temperature. Also, for charging via positive battery connection point the maximum charging voltage of 15.2 volt at room temperature must not be exceeded. The batter can be damaged even with short charging of the AGM battery with a charging voltage higher than 15.2 volts. A charging voltage of more than 15.2 V is usually used in quick-charging routines.
Installation location
The AGM battery must not be installed in the engine compartment on account of the high spatial temperature differences, otherwise its service life will be significantly shortened.
Housing
On no account may AGM batteries be opened, as the ingress of oxygen from the atmosphere would cause the battery to lose its chemical balance, rendering it unserviceable.