67 62 ... Notes on initializing power window unit (front)
NOTE:
Initialization
for a MINI merely involves normalization
, i.e. the mechanical end stop of the power window unit is recorded and stored. Learning the characteristic curve
is not required due to the lack of an anti-trapping mechanism.
NOTE:
An initialization must be performed:
- In the event of malfunctions, e.g. no one-touch function or no complete closing of the door glass after closing of the door.
- After disconnection of the battery negative lead.
- After replacement of the flat motor/power window unit.
- After work is carried out on the power window mechanism.
WARNING:
No anti-trapping mechanism!
NOTE:
Performing initialization:
- The reference point for initialization is the mechanical stop with the door closed and the window in its uppermost position.
- To initialize, raise the window glass and keep the switch depressed in the Lift position for approx. 5 seconds and then release.
- Checking initialization:
- Open door, window glass move down slightly.