Fuel Flow Signal Does Not Increase (Test C)

Turn ignition switch to "OFF" position. Disconnect 60-pin connector from EEC-IV module. Using an ohmmeter, check for continuity between terminal No. 7 of fuel computer harness connector and Pin No. 34 of EEC-IV module connector. See Figure . If okay, substitute a known good ECC-IV module and retest. If condition is still present, replace fuel computer. If not okay, check open in wiring between fuel computer connector and EEC-IV module.