Home >> Mercury >> 2009 >> Sable Base, AWD >> Repair and Diagnosis (Single Page) >> Brakes >> Traction Control >> Anti-Lock Brake System - Vehicle Dynamic Systems >> Diagnostic Tests >> Anti-Lock Control >> Pinpoint Tests >> Pinpoint Test D: DTC C1266 - ABS Valve Power Relay Circuit Failure >> Normal Operation

Normal Operation

The operating voltage required for ABS module isolation valve operation is in a range between 10 and 16 volts.

Fused battery voltage is supplied to the ABS module for the valves by battery junction box (BJB) fuse 12 (20A) along circuit SBB12 (GN/RD) and ground is provided along circuit GD120 (BK/GN).

This pinpoint test is intended to diagnose the following: