Pinpoint Test E: The Power Sliding Door Does Not Open Using The Remote Keyless Entry Transmitter
- E1 CHECK THE LOCK/UNLOCK OPERATION FROM THE REMOTE KEYLESS ENTRY (RKE) TRANSMITTER
- Operate the door locks from the RKE transmitter.
- Do the doors lock and unlock correctly?
- Yes : GO to E2 .
- No : To diagnose the inoperative door locks from the RKE transmitter, GO to PINPOINT TEST G .
- E2 CHECK THE RKE TRANSMITTER INPUT TO THE SJB
- Connect the diagnostic tool.
- Key in ON position.
- Enter the following diagnostic mode on the diagnostic tool: Smart Junction Box (SJB) PIDs.
Monitor the SJB RKE transmitter power sliding door PIDS while pressing the RKE transmitter open and close buttons.
- Do the PID values agree with the button presses?
- Yes : GO to E3 .
- No : REPLACE the RKE transmitter. PROGRAM all the RKE transmitters. REFER to REMOTE KEYLESS ENTRY TRANSMITTER PROGRAMMING . CLEAR the DTCs. REPEAT the self-test.
- E3 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . CLEAR the DTCs. REPEAT the self-test.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.