Preliminary Inspection
Verify the customer concern by operating the electronic door lock control system. Visually inspect the components of the electronic door lock control system for the following:
- Damaged door lock mechanisms
- Stuck or binding door lock
- Blown fuse(s): 15A ROOM LAMP, 30A POWER WINDOW or 10A ELECTRON BAT
- Damaged RH circuit breaker
- Damaged connectors
- Damaged keyless entry components
- Damaged power lock actuators
- Damaged door switches
- Broken or loose wiring
- Corroded or poor connections