Removal & Installation (Probe 2.5L)
- Disconnect negative battery cable. Remove fresh air duct nuts/bolts. Loosen spring clamp and slide air cleaner assembly forward. Remove fresh air duct. Disconnect distributor connectors. Remove distributor cap and gasket. Disconnect air duct from Volume Airflow (VAF) meter. Disconnect VAF meter connector.
- Remove fuel pressure regulator control solenoid from air cleaner, and position solenoid out of way. Remove air cleaner assembly. Remove 2 distributor hold-down bolts and distributor. To install, reverse removal procedure. Set base ignition timing. See appropriate ADJUSTMENTS article in the ENGINE PERFORMANCE section below.