LEMON Manuals: Even more car manuals for everyone
Home >> Mercury >> 1994 >> Tracer LTS, Automatic >> Repair and Diagnosis >> Engine Performance >> Remove, Overhaul & Install >> Engine Controls - Remove/Install/Overhaul >> Ignition System >> Distributor Removal & Installation >> Installation (Except Probe 2.5L)

Installation (Except Probe 2.5L)

  1. Ensure engine is at TDC of compression stroke. Rotate distributor rotor so reference marks nearly align. Insert distributor drive into engine.
  2. When installing distributor, rotor will rotate. Ensure reference marks are aligned when distributor is fully engaged in engine. To complete installation, reverse removal procedure. Set base ignition timing. See appropriate ADJUSTMENTS article in the ENGINE PERFORMANCE section below.