Circuit Test XB - Variable Control Relay Module (VCRM): No-Start
WARNING: This page is about a different variant/trim than selected.
- Inertia Fuel Shutoff (IFS) Switch Not Reset Or Open
- Open In Power-To-Fuel Pump Circuit Between Fuel Pump Monitor (FPM) Terminal At PCM (Terminal No. 8) And Fuel Pump
- Poor Fuel Pump Ground
- Open Circuit In Fuel Pump