Steering Column: Reassembly
To install, reverse removal procedure. Tighten intermediate shaft-to-universal joint bolt to 13-20 ft. lbs. (18-27 N.m). Tighten universal joint-to-column shaft bolt to 29-36 ft. lbs. (40-50 N.m). Install new lock mounting bracket bolts. Ensure proper operation of column lock. Tighten bracket bolts until heads break off.