Power Door Lock Relay
- Turn ignition switch to ON position.
- Measure voltages at specified relay terminals while locking or unlocking the door lock switch. See POWER DOOR LOCK RELAY TEST
table.
- Replace relay if operation is not as specified.
POWER DOOR LOCK RELAY TEST
| Wire |
Condition |
Specified Voltage |
| White/Green |
LOCK |
Greater Than 1 Volt |
| White/Green |
UNLOCK |
Greater Than 10 Volts |
| Black |
LOCK |
Less Than 1 Volt |
| Black |
UNLOCK |
Less Than 1 Volt |
| Green |
LOCK |
Greater Than 10 Volts |
| Green |
UNLOCK |
Less Than 1 Volt |
| Red |
LOCK |
Less Than 1 Volt |
| Red |
UNLOCK |
Greater Than 10 Volt |
| Green/Red |
LOCK |
Less Than 1 Volt |
| Green/Red |
UNLOCK |
Greater Than 10 Volts |
| Blue/Red |
LOCK |
Greater Than 10 Volts |
| Blue/Red |
UNLOCK |
Less Than 1 Volt |
| Green/Black |
LOCK |
Greater Than 10 Volts |
| Green/Black |
UNLOCK |
Greater Than 10 Volts |