LEMON Manuals: Even more car manuals for everyone
Home >> Mercury >> 1989 >> Tracer 2D Hatchback, Standard >> Repair and Diagnosis >> Engine Performance >> Sensor Range Charts >> Introduction >> FESTIVA (Fuel Injection) & Tracer

FESTIVA (Fuel Injection) & Tracer

TRACER AIRFLOW METER TERMINAL RESISTANCE

Terminal Fully Closed: Ohms Fully Open: Ohms
E2-Vs 20-400 20-1000
E2-Vc 100-300 100-300
E2-Vb 200-400 200-400
E2-THA -4°F (-20°C) 13.6-18.4k -4°F (-20°C) 13.6-18.4k
E2-THA 68°F (20°C) 2.2-2.7k 68°F (20°C) 2.2-2.7k
E2-THA 140°F (60°C) 500-700 140°F (60°C) 500-700
E1-Fc Infinite 0
Fig 1: Festiva & Tracer Airflow Meter Connector
G93383Courtesy of MAZDA MOTORS CORP.
COOLANT TEMPERATURE SENSOR RESISTANCE

Temperature: °F (°C) Resistance: Ohms
1.3L
-4 (-20) 14,600-17,800
68 (20) 2,300-2,700
176 (80) 200-400
1.6L
50 (10) 58,750
65 (18) 40,500
180 (82) 3,600
220 (104) 1,840
TPS RESISTANCE

Test Condition (1) Cont. Between IDL-TL Cont. Between PSW-TL
.02" (.5 mm) Yes No
.03" (.7 mm) No No
Wide Open Throttle No Yes
(1) Insert specified thickness gauge between throttle adjustment screw and stop lever.