Engine Cranks But Will Not Start
- Ensure correct starting procedure has been followed. Turn ignition to "RUN". Use a 12 volt test lamp to determine if voltage is available at fuel shut-off solenoid.
- If no voltage is present, check electrical circuit. If voltage is present but solenoid does not operate, replace fuel shut-off solenoid.
- If solenoid is OK, loosen 1 injector line nut at a time and crank engine. If fuel does not discharge, go to Fuel System Testing. If fuel discharges, go to Glow Plug Control Diagnosis.