See following pages for REMOVAL  and INSTALLATION  of each component. After replacement or repaired component installed, connect lines as directed below.

In addition to checking and adjusting the compressor oil level (see COMPRESSOR OIL CHECK ), certain component replacement requires additional refrigeration oil. Add specified amounts of oil directly to the component prior to installation.

Application Amount
With G.M. Compressor
  Evaporator 3 oz.
  Condenser 1 oz.
  Accumulator or Receiver-Drier 1 oz.
With Air-Temp Compressor
  Evaporator 2 oz.
  Condenser 1 oz.
  Receiver-Drier 1 oz.

THERMAL LIMITER NOTE - On vehicles equipped with a Low Refrigerant Charge Protection System (Superheat Switch and Thermal Limiter), if compressor operation is required before full system refrigerant charge is obtained, disconnect the thermal limiter and connect a jumper wire between terminals "B" and "C" of the limiter. When system adjustments and repairs are complete, and full system charge is obtained, reconnect thermal limiter to its original condition. This is required in order to prevent thermal limiter from sensing the low refrigerant and stopping system operation.