Combustion Engine Forced Start, Basic Function - GF07.10-P-1059A
Engine all (CAR)
Overview
This document contains information on:
- General
- Function requirements
- Function
General
The forced engine start ensures that the engine can still run in the event of insufficient supply to the on-board electrical system. In this case, the engine is autonomously force started by the combustion engine control unit.
Function requirements
- Coolant temperature > 115 °C
- Exceeding of engine stop period > 3 min
- Vehicle speed > 2 km/h in forward travel
- Rolling backwards
- The ECO start/stop function is deactivated.
- On-board network condition requires the engine to run.
- Brake assistance or distance control system in control intervention function
- Vacuum at brake booster not in specified range
- Air conditioning system requires engine to be running.
- System or communication error in the following systems: steering, on-board electrical system, brake system, accelerator pedal, transmission, engine
Function
A forced engine start is also conducted if the stability of the on-board electrical system can no longer be assured, e.g. as a consequence of load-intensive consumers. The engine will continue to run until sufficient stability of the on-board electrical system can be ensured.
The ECO start/stop function is switched off if the stability of the on-board electrical system is not assured.
| Additional basic functions | |||
| Combustion engine control unit, basic function | GF07.08-P-9890A | ||