LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> C43 AMG 2D Convertible >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Mixture Formation - 205 Chassis - 1 Of 2 >> Basic Knowledge >> Starting, Function >> Starting, Function - GF07.10-P-1001MMV

Starting, Function - GF07.10-P-1001MMV

Engine 276.8 in model 205, 253 

Starting function requirements, general points 

Starting, general points 

The ME-SFI [ME] control unit (N3/10) reads in the following signals for starting:

The ME-SFI [ME] control unit actuates the following components to start the engine:

The ME-SFI [ME] control unit coordinates the injection and firing order during starting based on the signals from the crankshaft Hall sensor and the camshaft Hall sensors.

The starter control in the ME-SFI [ME] control unit takes on actuation and cutout of the starter.

Function sequence for start 

The starter control is subdivided into the following points:

Function sequence for start begin 

When the ignition key (transmitter key (A8/1)) is moved into the start position, the ME-SFI [ME] control unit receives the "circuit 50 signal" from electronic ignition lock control unit via the chassis FlexRay, powertrain control unit and drive train CAN.

The ME-SFI [ME] control unit uses a ground signal to actuate the starter circuit 50 relay (K40/8kH) on both sides. The power contact on the starter relay closes and the starter solenoid switch is supplied at "circuit 50" with voltage from "circuit 30".

Function sequence for start end 

Starter control is carried out automatically by the ME-SFI [ME] control unit (touch start). This means that once the start process is initiated, switching off "circuit 50" will have no further influence on the start procedure.

When engine cranking speed has reached 400 to 700 RPM, or after a starting time of 5 to 40 s (dependent on coolant temperature), the ME-SFI [ME] control unit interrupts the negative activation of the circuit 50 starter relay and thus terminates the starting procedure.

IMPORTANT The starting procedure can only be aborted by switching off the ignition.

IMPORTANT A voltage dip limiter is installed at the positive battery terminal. Its task is to prevent a drop in the battery voltage below a defined voltage value during the starting procedure of the engine.

This is realized through limitation of the starter current some of the time. Note here that 12 V is only present at the starter positive line during the starting procedure.

  Electrical function schematic for starting   PE07.10-P-2701-97FBB
  Overview of system components for gasoline injection and ignition system with direct injection   GF07.70-P-9998MMV