Service Campaign 2018010007 - Update HERMES Control Unit Software February 2018 (P-SC-2018010007)
Publication date: 2018-02-01Reference number: P-SC-2018010007
SERVICE CAMPAIGN 2018010007 - UPDATE HERMES CONTROL UNIT SOFTWARE FEBRUARY 2018
SERVICE CAMPAIGN BULLETIN
| MERCEDES-BENZ: | Models 117, 156, 166, 172, 190, 205, 207, 213, 217, 218, 222, 231, 242, 253, and 292 Model Years 2017 and 2018 |
SUBJECT
Models 117, 156, 166, 172, 190, 205, 207, 213, 217, 218, 222, 231, 242, 253, and 292 Model Years 2017 and 2018
- Update Hermes Control Unit Software
Daimler AG ("DAG"), the manufacturer of Mercedes-Benz vehicles, has determined that on certain MY17 and MY18 CLA-Class (117 platform), GLA-Class (156 platform), GLE-Class (166 platform), SLK-Class (172 platform), AMG GT (190 platform), C-Class (205 platform), E-Class Coupe (207 platform), E-Class (213 platform), S-Class Coupe (217 platform), CLS-Class (218 platform), S-Class (222 platform), SL-Class (231 platform), B-Class (242 platform), GLC-Class (253 platform), and GLE-Coupe (292 platform) vehicles, the HERMES control unit software may not meet current series production specifications. An authorized Mercedes-Benz dealer will update the HERMES control unit software for the affected vehicles.
Prior to performing this Service Campaign:
- Please check VMI to determine if the vehicle is involved in the Campaign and if it has been previously repaired.
- Please review the entire Service Campaign bulletin and follow the repair procedure exactly as described.
Approximately 26,149 vehicles are affected.
Order No. P-SC-2018010007
This bulletin has been created and maintained in accordance with MBUSA-SLP S423QH001, Document and Data Control, and MBUSA-SLP S424HH001, Control of Quality Records.
- Use DAS/Xentry 09/2017 with all associated patches or higher.
- Follow the steps exactly as described in DAS/Xentry.
- Connect battery charger (battery voltage >12.5V).
- Ensure all electrical consumers are switched-off.
- In the event of software/SCN update issues, contact Star Diagnosis User Help Desk. Please refer to the "pre-call" check list before contacting UHD
- Refer to Star Diagnosis System (SDS) Best Practices Guide.
PROCEDURE
- Update HERMES control unit software.
To do so, select menu item "Control units view Information and communication Control unit for telematics services Adaptations Control unit update Update of control unit software".
Then follow the user guidance in XENTRY DIAGNOSTICS/DAS.
WARRANTY INFORMATION
Operation: Connect/disconnect battery charger (02-5058)
Star Diagnosis System (SDS), Connect/disconnect (02-4762) Update HERMES control unit software (02-9334)
| Damage Code | Operation Number | Labor Time (hrs.) |
|---|---|---|
| 54 991 50 8 | 02-5058 | 0.1 |
| 02-4762 | 0.1 | |
| 02-9334 | 0.1 |
If two or more software updates or SCN codings are performed during a workshop visit, the operation items 02-4762 and 02-5058 can be invoiced only once for each workshop order!