Power Electronics DTCS (LE-Tube)
POWER ELECTRONICS DTCS (LE-TUBE)
| MB DTC | Description |
|---|---|
| B2735-00 | The squib for pyrofuse 'On-board electrical network line' has a malfunction. |
| P0562-00 | The on-board power supply voltage is too low. |
| P0563-00 | The on-board power supply voltage is too high. |
| P0604-00 | There is an internal control unit fault in the RAM memory. |
| P0605-00 | There is an internal control unit fault in the ROM memory. |
| P060B-00 | There is an internal control unit fault in the analog/digital converter. |
| P060C-00 | There is an internal control unit fault in the central processing unit. |
| P061A-00 | The torque control of the control unit has a malfunction. |
| P062F-00 | There is an internal error in the EEPROM of the control unit. |
| P0634-00 | The temperature in the control unit is too high. |
| P0666-00 | The internal temperature sensor of the control unit has an electrical fault. |
| P0668-00 | The internal temperature sensor of the control unit has a short circuit to ground. |
| P0A05-00 | The actuation of the circulation pump for the low-temperature circuit has an open circuit. |
| P0A07-00 | The actuation of the circulation pump for the low-temperature circuit has a short circuit to positive. |
| P0A0A-00 | The interlock circuit of the high-voltage on-board electrical system has an electrical fault. |
| P0A0B-00 | The interlock circuit of the high-voltage on-board electrical system has a malfunction. |
| P0A0C-00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to ground. |
| P0A0D-00 | The interlock circuit of the high-voltage on-board electrical system has a short circuit to positive. |
| P0A0E-00 | The interlock circuit of the high-voltage on-board electrical system has a sporadic malfunction. |
| P0A1C-00 | Control unit 'Electric machine B' has a malfunction. |
| P0A31-00 | Temperature sensor 'Electric machine B' has a malfunction. |
| P0A32-00 | Temperature sensor 'Electric machine B' has a short circuit to ground. |
| P0A33-00 | Temperature sensor 'Electric machine B' has a short circuit to positive. |
| P0A34-00 | The temperature sensor 'Electric machine B' has a sporadic malfunction. |
| P0A35-00 | Electric machine B has overtemperature. |
| P0A3D-00 | Inverter 'Electric machine B' has overtemperature. |
| P0A46-00 | Position sensor 'Electric machine B' has a malfunction. |
| P0A46-4B | Position sensor 'Electric machine B' has a malfunction. There is a fault due to overtemperature. |
| P0A46-61 | Position sensor 'Electric machine B' has a malfunction. The signal calculation is faulty. |
| P0A46-64 | Position sensor 'Electric machine B' has a malfunction. There is an implausible signal. |
| P0A4A-00 | Position sensor 'Electric machine B' has detected excessively high rpm. |
| P0A67-00 | The current value of phase U of electric machine B is too low. |
| P0A68-00 | The current value of phase U of electric machine B is too high. |
| P0A6A-00 | The current value of phase V of electric machine B is too low. |
| P0A6B-00 | The current value of phase V of electric machine B is too high. |
| P0A6D-00 | The current value of phase W of electric machine B is too low. |
| P0A6E-00 | The current value of phase W of electric machine B is too high. |
| P0A79-00 | Inverter 'Electric machine B' has a malfunction. |
| P0A87-00 | Current sensor A of the DC/DC converter has a malfunction. |
| P0A8B-00 | The power supply for the DC/DC converter is implausible. |
| P0A8D-00 | The power supply for the DC/DC converter is too low. |
| P0A8E-00 | The power supply for the DC/DC converter is too high. |
| P0A91-00 | Electrical Machine B has a malfunction. |
| P0A94-00 | The control unit 'DC/DC converter' has a malfunction. |
| P0AF3-00 | Temperature sensor 1 of inverter 'Electric machine B' has a malfunction. |
| P0AF4-00 | Temperature sensor 1 of inverter 'Electric machine B' has a short circuit to ground. |
| P0AF6-00 | Temperature sensor 1 of the inverter 'Electric machine B' has a sporadic malfunction. |
| P0AF7-00 | Control unit ""DC/DC converter"" has overtemperature. |
| P0AFA-00 | The power supply of the high-voltage on-board electrical system is too low. |
| P0AFB-00 | The power supply of the high-voltage on-board electrical system is too high. |
| P0AFB-FA | The power supply of the high-voltage on-board electrical system is too high. |
| P0B38-00 | The actuation of circulation pump 2 for the low temperature circuit has an open circuit. |
| P0B3A-00 | The actuation of circulation pump 2 for the low temperature circuit has a short circuit to positive. |
| P0BF2-00 | The current sensor for phase U of electric machine B has a malfunction. |
| P0BF3-00 | The current sensor for phase U of electric machine B has a short circuit to ground. |
| P0BF4-00 | The current sensor for phase U of electric machine B has a short circuit to positive. |
| P0BF6-00 | The current sensor for phase V of electric machine B has a malfunction. |
| P0BF7-00 | The current sensor for phase V of electric machine B has a short circuit to ground. |
| P0BF8-00 | The current sensor for phase V of electric machine B has a short circuit to positive. |
| P0BFA-00 | The current sensor for phase W of electric machine B has a malfunction. |
| P0BFB-00 | The current sensor for phase W of electric machine B has a short circuit to ground. |
| P0BFC-00 | The current sensor for phase W of electric machine B has a short circuit to positive. |
| P0BFE-00 | The values of the current sensors for phases U-V-W of electric machine B are implausible relative to each other. |
| P0C04-00 | The current value of electric machine B is too high. |
| P0C18-00 | The teach-in process of position sensor 'Electric machine B' was not performed. |
| P0C31-00 | The cooling system for low temperature circuit B has a malfunction. |
| P0C39-00 | Temperature sensor A of the DC/DC converter has a malfunction. |
| P0C3A-00 | Temperature sensor A of the DC/DC converter has a short circuit to ground. |
| P0C3B-00 | Temperature sensor A of the DC/DC converter has a short circuit to positive. |
| P0C3C-00 | Temperature sensor A of the DC/DC converter has a sporadic malfunction. |
| P0C3E-00 | Temperature sensor B of the DC/DC converter has a malfunction. |
| P0C3F-00 | Temperature sensor B of the DC/DC converter has a short circuit to ground. |
| P0C40-00 | Temperature sensor B of the DC/DC converter has a short circuit to positive. |
| P0C41-00 | Temperature sensor B of the DC/DC converter has a sporadic malfunction. |
| P0C4F-00 | The learned value of position sensor 'Electric machine B' is outside the valid range. |
| P0C55-00 | Electric circuit 1 of position sensor 'Electric machine B' has an electrical fault. |
| P0C5F-00 | Electric circuit 2 of position sensor 'Electric machine B' has an electrical fault. |
| P0C73-00 | Circulation pump 1 for the low-temperature circuit has a malfunction. |
| P0C74-00 | Circulation pump 2 for the low-temperature circuit has a malfunction. |
| P0C76-00 | The discharge time in the high-voltage on-board electrical system is too long. |
| P0DA4-00 | Sensor 'Voltage of high-voltage on-board electrical system' in control unit 'Electric machine B' has a malfunction. |
| P0DA9-00 | The value of the sensor 'Voltage of high-voltage on-board electrical system' in control unit 'Electric machine B' is implausible. |
| P0E59-00 | Temperature sensor C of the DC/DC converter has a malfunction. |
| P0E5A-00 | Temperature sensor C of the DC/DC converter has a short circuit to ground. |
| P0E5B-00 | Temperature sensor C of the DC/DC converter has a short circuit to positive. |
| P0E5C-00 | Temperature sensor C of the DC/DC converter has a sporadic malfunction. |
| P13F7-00 | The torque request from the control unit is implausible. |
| P1603-00 | The torque requested from electric machine B is outside the valid range. |
| P1604-00 | The control unit is not coded. |
| P1605-00 | The assignment of phases U-V-W is implausible when compared against the control unit coding. |
| P1606-00 | The control unit has a malfunction due to redundant monitoring. |
| P1607-00 | The watchdog function has detected an internal software error. |
| P1609-00 | The system base chip of the control unit has a malfunction. |
| P1644-00 | An incorrect variant coding or configuration was detected. |
| P1ABC-00 | The power supply of the high-voltage on-board electrical system for control unit 'DC/DC converter' is too low. |
| P1ABD-00 | The power supply of the high-voltage on-board electrical system for control unit 'DC/DC converter' is too high. |
| P1AEC-00 | Sensor 'Voltage of high-voltage on-board electrical system' in control unit 'Electric machine B' has a malfunction. |
| P1AF9-00 | Control unit 'Electric machine B' has performed a requested system shutoff. |
| P1B90-00 | The power consumption from the on-board electrical system or the current supply into the on-board electrical system is too high. |
| P1B91-00 | The power consumption from the high-voltage on-board electrical system or the current supply into the high-voltage on-board electrical system is too high. |
| P1C51-00 | The charging process of the high-voltage battery module was aborted. |
| P1C5D-00 | The current value of the on-board electrical system is outside the valid range. |
| P1C5E-00 | Voltage sensor A of the DC/DC converter has a malfunction. |
| P1C5F-00 | Sensor 'Voltage of on-board electrical system' in control unit 'DC/DC converter' has a malfunction. |
| P1C61-00 | The power consumption from the on-board electrical system is too high. |
| P1C70-00 | The contact of the ground strap is faulty. |
| P1C71-00 | There is a warning about poor contact of the ground strap. |
| P1C77-00 | There is an advance warning about poor contact of the ground strap. |
| P1C80-00 | The high-voltage component lockout is active. |
| P1CB4-00 | The power supply for circuit 30c has a malfunction. |
| P1D95-00 | The current value of the D-axis is implausible. |
| P267F-00 | The temperature sensor of the control unit has a malfunction. |
| U0076-00 | Hybrid CAN bus OFF error |
| U0100-00 | Communication with the control unit 'combustion engine' has a malfunction. |
| U0101-00 | Communication with control unit ""Transmission"" has a malfunction. |
| U0112-00 | Communication with control unit 'High-voltage battery' has a malfunction. |
| U0122-00 | Communication with control unit 'Traction system' has a malfunction. |
| U0129-00 | Communication with control unit ""Regenerative braking system"" has a malfunction. |
| U0142-00 | Communication with the rear signal acquisition and actuation module has a malfunction. |
| U0146-00 | Communication with the central gateway has a malfunction. |
| U0155-00 | Communication with the instrument cluster has a malfunction. |
| U0168-00 | Communication with the electronic ignition lock has a malfunction. |
| U0401-00 | Implausible data were received from control unit 'combustion engine'. |
| U0402-00 | Implausible data were received from control unit 'Transmission'. |
| U0416-00 | Implausible data were received from control unit 'Traction system'. |
| U0418-00 | Implausible data were received from control unit ""Regenerative braking system"". |
| U0427-00 | Implausible data were received from the electronic ignition lock. |
| U0447-00 | Implausible data were received from the central gateway. |
| U3001-00 | The control unit was switched off improperly. |
| U300E-00 | Input signal ""Circuit 15 ON"" is implausible. |
| U3017-00 | The real-time internal control unit clock has a malfunction. |