LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2016 >> C350e >> Repair and Diagnosis >> Electrical >> Charging Systems >> Electrical Drive System - 205 Chassis >> Basic Knowledge >> Electric Drive Low-Temperature Circuit, Basic Function - GF08.50-P-1001A

Electric Drive Low-Temperature Circuit, Basic Function - GF08.50-P-1001A

Model all (CAR) with code ME01 (Electric motor) 

Model all (CAR) with code ME05 (HYBRID DRIVE 80KW VARIANT (INCLUDING PLUGIN)) 

Model all (CAR) with code ME08 (Hybrid drive 75-84 kW VARIANT (INCLUDING PLUGIN)) 

Overview 

This document contains information on:

The following components are cooled or heated via the electric drive low-temperature circuit:

IMPORTANT The following applies for hybrid vehicles: The electric drive low-temperature circuit is separated from the combustion engine cooling circuit and has a separate expansion reservoir.

IMPORTANT The following applies to hybrid vehicles: The electric machine is cooled by the transmission oil.

Function requirements 

Electric drive low-temperature circuit (low-temperature circuit 1) 

The following applies for electric vehicles: 

The powertrain control unit evaluates the temperatures of the electric machine, electric machine 2 (electric vehicle), DC/DC converter control unit and AC charger for high-voltage battery (electric vehicle). It calculates the required coolant flow volume and accordingly actuates the circulation pump of low-temperature circuit 1. To support this control, the low-temperature coolant circuit 1 temperature sensor is also evaluated.

The circulation pump pumps the coolant into low-temperature circuit 1.

The components connected to the cooling circuit output heat into the coolant.

The coolant then flows into the radiator low-temperature circuit where it is cooled down by the airstream or the air flow of the fan motor and flows back to the circulation pump. The powertrain control unit actuates the fan motor and radiator shutters to control the cooling output at the cooler. In the case of an increasing cooling output requirement, the radiator shutters are initially actuated to increase the air flow. The fan motor is then actuated according to the cooling requirement.

There is also a self-regulating thermostat in the circuit. This separates the cooler from the circuit so long as the coolant is below a certain temperature and there is no cooling requirement.

The following applies for hybrid vehicles: 

The power electronics control unit evaluates the temperature of the low-temperature circuit 1 and requests, if necessary, the cooling output from the powertrain control unit.

The powertrain control unit evaluates the request for charge air, transmission, and power electronics cooling and accordingly actuates the circulation pump and, if necessary, the low-temperature circuit switchover valve. The low-temperature circuit temperature sensor is also evaluated to support this regulation.

The circulation pump causes the circulation of the coolant in low-temperature circuit 1. The component parts that are connected to the cooling circuit output heat into the coolant.

In the low-temperature circuit cooler, the coolant is cooled by the airstream or the air flow of the fan motor and flows back into the cooling circuit. The powertrain control unit actuates the fan motor and radiator shutters to control the cooling output at the cooler. In the case of an increasing cooling output requirement, the radiator shutters are initially actuated to increase the air flow. The fan motor is then actuated according to the cooling requirement.

To prevent hot combustion engine coolant from crossing into low-temperature circuit 1, a thermal shutoff valve closes the filling hose to the common expansion reservoir from a combustion engine coolant temperature of approx. 60°C.

IMPORTANT A min. coolant volume flow continues to flow through the components connected to the cooling circuit also at very low outside temperatures (depending on the coolant temperature).

  Detailed information     
  Electric drive low-temperature circuit, detailed information Model 293 with code ME01 (Electric motor) GF08.50-P-1102A
    Model 167 with code ME05 (HYBRID DRIVE 80KW VARIANT (INCLUDING PLUGIN)) GF08.50-P-1102B
    Model 177, 247 with code ME08 (Hybrid drive 75-84 kW VARIANT (INCLUDING PLUGIN)) GF08.50-P-1102D
  Additional basic functions     
  Electric machine, basic function   GF08.10-P-2000A
  Function schematics     
  Function schematic for electric drive low-temperature circuit Model 293 with code ME01 (Electric motor) PE08.50-P-2501-97A
    Model 167 with code ME05 (HYBRID DRIVE 80KW VARIANT (INCLUDING PLUGIN)) PE08.50-P-2501-97B
    Model 177, 247 with code ME08 (Hybrid drive 75-84 kW VARIANT (INCLUDING PLUGIN)) PE08.50-P-2501-97D
  Control units     
  Electric drive powertrain control unit, basic function Model all (CAR) with code ME01 (Electric motor) GF08.20-P-9892A 
  Powertrain control unit, basic function Model all (CAR) with code ME05 (HYBRID DRIVE 80KW VARIANT (INCLUDING PLUGIN))
Model all (CAR) with code ME08 (Hybrid drive 75-84 kW VARIANT (INCLUDING PLUGIN))
GF54.21-P-9894A
  Components     
  Low-temperature circuit temperature sensor, basic function   GF20.00-P-2000A
  Low-temperature circuit switchover valve, basic function   GF20.00-P-2001A
  Low-temperature circuit coolant pump, basic function   GF20.10-P-2006A