Home >> Mercedes Benz >> 2011 >> ML450 >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Interior/Illumination Lights >> Electrical System - Body - 164 Ml Class - 5 Of 6 >> Basic Knowledge >> Restraint system control unit data, function >> Restraint system control unit data, function - GF82.95-P-3005GQU

Restraint system control unit data, function - GF82.95-P-3005GQU

MODEL 164.1 with CODE (359) TELE AID emergency call system as of model year 09/YoM 08 model refinement package 

MODEL 164.8 with CODE (359) TELE AID emergency call system as of model year 09/YoM 08 

MODEL 251.0 with CODE (359) TELE AID emergency call system as of model year 09/YoM 08 

MODEL 251.1 with CODE (359) TELE AID emergency call system as of model year 09/YoM 08 

Function requirements 

General 

In the event of an accident with airbag actuation, an automatic emergency call (E-Call) is transmitted immediately. An emergency call is sent out regardless of the severity of the accident.

Function sequence 

The emergency call system control unit (N123/4) receives the crash data on the one hand via a discrete line as digital crash signal from the restraint systems control unit and, on the other hand, of the following (redundant) path, including crash level:

IMPORTANT The restraint systems control unit sends a LIFE signal (the LIFE signal is the "life sign" from the restraint systems control unit) every t = 500 ms over the same path as the crash information including crash level. This allows the emergency call system control unit to permanently monitor communication with the restrain systems control unit and proper function of the crash recognition.

REFER TO SYSTEM WIRING DIAGRAMS Electrical function diagram for data from restraint systems control unit, function Model 164 PE82.95-P-2063-97MAA
Model 251 PE82.95-P-2063-97RAA
  Restraint systems control unit, component description N2/7 GF91.60-P-4048GM
  Central gateway control unit, component description N93 GF54.21-P-4170GM
  Emergency call system control unit, component description N123/4 GF82.95-P-3212GQU