LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2001 >> S430 >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control -- Basic Knowledge -- 215 & 220 Chassis >> Basic Knowledge >> Temperature control function - GF83.57-P-2000 >> Temperature control function - GF83.57-P-2000I

Temperature control function - GF83.57-P-2000I

MODEL 220 

Fig 1: Identifying Temperature Control Interlinkage Components
G04851446

Function 

The electronically controlled cooling, heating and ventilation part of the automatic air conditioning and rear compartment air conditioning reaches or maintains constant the required interior temperature in the fastest possible time by:

Automatic basic setting of the temperature set values 

The basic setting has been defined at 22 °C.

Every side is automatically (individually) set to this value if the respective belt buckle is not engaged and, at the same time, the driving speed v > 20 km/h is exceeded. This function is carried out only once during ignition ON.

If the rear compartment air conditioning is fitted, it will be informed of this by the automatic air conditioning, as the belt buckles cannot be evaluated by the rear compartment air conditioning.

The DAS can read out the code for the automatic basic setting via the electronic ignition switch (EIS).

On vehicles with rear compartment air conditioning (code 582) 

The vaporizer temperature sensor measures the air temperature at the vaporizer outlet in the rear compartment.

The electronic control of the rear compartment air conditioning pushbutton control module compares the measured value with the temperature preselected at the temperature pushbuttons. Depending on demand, the electronic control alters the settings of the rear compartment air conditioning by operating the refrigerant shut-off valve or maintaining the particular setting constant.

  Duo valve location/task/function   GF83.20-P-2107I 
    With code 582 (rear compartment air conditioning) GF83.20-P-2107M 
  Heater heat exchanger location/task/function   GF83.20-P-2108I 
    With code 582 (rear compartment air conditioning) GF83.20-P-2108M 
  Hot water circulating pump location/task/ function   GF83.20-P-2109I 
    With code 582 (rear compartment air conditioning) GF83.20-P-2109M 
  Vaporizer location/task/design/function   GF83.40-P-2121I 
  Expansion valve position/task/design/function   GF83.40-P-2123I 
  Temperature button location/task/function   GF83.40-P-2141I 
  Shut-off valve refrigerant rear compartment air conditioning location/task/function With code 582 (rear compartment air conditioning) GF83.50-P-2103M 
  Temperature button rear compartment air conditioning location/task/function With code 582 (rear compartment air conditioning) GF83.50-P-2106M 
  Vaporizer Rear compartment air conditioning location/task/function With code 582 (rear compartment air conditioning) GF83.50-P-2111M 
  Refrigerant compressor position/task/design/ function   GF83.55-P-2100I 
  Control valve refrigerant compressor location/ task/function   GF83.55-P-2102I 
  Temperature sensor interior air with ventilating blower location/task/function   GF83.57-P-2107I 
  Temperature sensor Heat exchanger location/task/function   GF83.57-P-2108I 
    With code 582 (rear compartment air conditioning) GF83.57-P-2108M 
  Temperature sensor Vaporizer location/task/ function   GF83.57-P-2109I 
    With code 582 (rear compartment air conditioning) GF83.57-P-2109M 
  Temperature sensor outside air location/task/function   GF83.57-P-2110I 
  Sun sensor location/task/function   GF83.57-P-2111I