DTC Description (Modulating Pressure Regulating Solenoid)
- Fault Memory & Actuation Of MIL - MIL is turned on after 2 consecutive driving cycles with fault.
- Frequency Of Testing - Continuous.
- Checked Signal Or Status - Actuation of modulator pressure regulating solenoid valve.
- Short Circuit To Ground Limit Value - Less than 0.4 volts.
- Voltage Lower Limit Value - Approximately 8.5 volts.
- Voltage Upper Limit Value - Approximately 15 volts.
- Current Lower Limit Value - Approximately 0.300 amps.
- Current Upper Limit Value - Approximately 0.700 amps.
- Duration Of Test - Approximately one second.
NOTE:
Faults (actuation, open circuit, short circuit or short in valve) recognized by the Electronic Transmission Control (ETC) module and sent to the ME-SFI control module via the Controller Area Network (CAN) data bus. The ME-SFI control module carries out fault memory and actuation of Malfunction Indicator Light (MIL). Also read out ETC fault memory for fault code 6.