LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2000 >> ML430 >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel System -- 163 Chassis >> Functions, AS-Built Config., Technical Data, system component >> Activated charcoal canister shutoff valve location/task/design/ function - GF47.30-P-4033L

Activated charcoal canister shutoff valve location/task/design/ function - GF47.30-P-4033L

MODEL 129 

with ENGINE 104.943 /991 as of 1.8.96, 

112.923/943,113.961,119.982,120.983 with CODE (494a) USA version 

MODEL 140 

with ENGINE 104.944 /994 as of 1.8.96, 

119.981 /980,120.982 with CODE (494a) USA version 

MODEL 163 with ENGINE 112.942/970,113.942 /965 with CODE (494a) USA version MODEL 170 

with ENGINE 111.946 as of 1.6.98, 

111.943 /973 /983,112.947 with CODE (494a) USA version 

MODEL 202 

with ENGINE 104.941 as of 1.8.96, 

111.921 as of 1.9.98, 

111.974, 

111.975 as of 1.8.96 

, 111.944/945,112.910 /920 with CODE (494a) USA version 

MODEL 203 with ENGINE 112.912/916/946 /953 with CODE (494a) USA version 

MODEL 208 with ENGINE 111.944/975,112.940,113.943 with CODE (494a) USA version 

MODEL 209 with ENGINE 112.912/955, 113.968 with CODE (494a) USA version 

MODEL 210 with ENGINE 104.995, 112.911 /914/921 /941, 113.940, 119.985/980 with CODE (494a) USA version 

MODEL 215 with ENGINE 113.960,137.970 with CODE (494a) USA version 

MODEL 220 with ENGINE 112.944 /972 /975, 113.941 /948 /960 /966, 137.970 with CODE (494a) USA version 

MODEL 230 with ENGINE 112.973,113.963 with CODE (494a) USA version 

MODEL 211 with ENGINE 112.913 /917 /949 /954, 113.967 /969 with CODE (494a) USA version 

Shown in the design of model 210 

Fig 1: Identifying Activated Charcoal Canister Shutoff Valve Design - Shown In The Design Of Model 210
G04607576
  Activated charcoal canister shutoff valve position Located on the top at the vent connection of the activated charcoal canister.  
Model 129 as of 9/97 GF47.30-P-4033-01A
Model 140 GF47.30-P-4033-01S
Model 163 GF47.30-P-4033-01GH 
Model 170 GF47.30-P-4033-01G
Model 202 as of 10/97 GF47.30-P-4033-01E
Model 203, 209 GF47.30-P-4033-01P
Model 208 GF47.30-P-4033-01K
Model 215, 220 GF47.30-P-4033-01M
Model 230 GF47.30-P-4033-01RA
  Activated charcoal canister shutoff valve task Close the ventilation of the activated charcoal canister for a leakage test of the fuel system.  
  Activated charcoal canister shutoff valve design Solenoid which closes the valve when energizing. Additionally a mechanical safety valve is installed.  
  Activated charcoal canister shutoff valve function The activated charcoal canister shutoff valve (Y58/4) is actuated at the ground end by the ME control unit to conduct the leak test of the fuel system. In case of errors in the shutoff valve (valve does not open) a mechanical safety valve (as of approx. 25 mbar) takes over the aeration of the activated charcoal canister (77).