Activated charcoal canister shutoff valve location/task/design/ function - GF47.30-P-4033L
MODEL 129
with ENGINE 104.943 /991 as of 1.8.96,
112.923/943,113.961,119.982,120.983 with CODE (494a) USA version
MODEL 140
with ENGINE 104.944 /994 as of 1.8.96,
119.981 /980,120.982 with CODE (494a) USA version
MODEL 163 with ENGINE 112.942/970,113.942 /965 with CODE (494a) USA version MODEL 170
with ENGINE 111.946 as of 1.6.98,
111.943 /973 /983,112.947 with CODE (494a) USA version
MODEL 202
with ENGINE 104.941 as of 1.8.96,
111.921 as of 1.9.98,
111.974,
111.975 as of 1.8.96
, 111.944/945,112.910 /920 with CODE (494a) USA version
MODEL 203 with ENGINE 112.912/916/946 /953 with CODE (494a) USA version
MODEL 208 with ENGINE 111.944/975,112.940,113.943 with CODE (494a) USA version
MODEL 209 with ENGINE 112.912/955, 113.968 with CODE (494a) USA version
MODEL 210 with ENGINE 104.995, 112.911 /914/921 /941, 113.940, 119.985/980 with CODE (494a) USA version
MODEL 215 with ENGINE 113.960,137.970 with CODE (494a) USA version
MODEL 220 with ENGINE 112.944 /972 /975, 113.941 /948 /960 /966, 137.970 with CODE (494a) USA version
MODEL 230 with ENGINE 112.973,113.963 with CODE (494a) USA version
MODEL 211 with ENGINE 112.913 /917 /949 /954, 113.967 /969 with CODE (494a) USA version
Shown in the design of model 210
| Activated charcoal canister shutoff valve position | Located on the top at the vent connection of the activated charcoal canister. | ||
| Model 129 as of 9/97 | GF47.30-P-4033-01A | ||
| Model 140 | GF47.30-P-4033-01S | ||
| Model 163 | GF47.30-P-4033-01GH | ||
| Model 170 | GF47.30-P-4033-01G | ||
| Model 202 as of 10/97 | GF47.30-P-4033-01E | ||
| Model 203, 209 | GF47.30-P-4033-01P | ||
| Model 208 | GF47.30-P-4033-01K | ||
| Model 215, 220 | GF47.30-P-4033-01M | ||
| Model 230 | GF47.30-P-4033-01RA | ||
| Activated charcoal canister shutoff valve task | Close the ventilation of the activated charcoal canister for a leakage test of the fuel system. |
| Activated charcoal canister shutoff valve design | Solenoid which closes the valve when energizing. Additionally a mechanical safety valve is installed. | ||
| Activated charcoal canister shutoff valve function | The activated charcoal canister shutoff valve (Y58/4) is actuated at the ground end by the ME control unit to conduct the leak test of the fuel system. In case of errors in the shutoff valve (valve does not open) a mechanical safety valve (as of approx. 25 mbar) takes over the aeration of the activated charcoal canister (77). |