Test 3.0: Central Locking System "Open" Signal
- Connect Hand-Held tester (HHT) to diagnostic connector. Select LOCKNUT SWITCH 1 on HHT display. Monitor readings. Attempt to unlock doors using remote transmitter and key. If YES is displayed, system is okay. If NO is displayed, go to next step.
- Connect harness adapter and breakout box to anti-theft control module connector. Measure voltage between terminals No. 1 and 11 at breakout box. Attempt to unlock doors using remote transmitter and key. Battery voltage should exist. If battery voltage does not exist, check wiring. See WIRING DIAGRAMS . Diagnose central locking system.