Operating the deployment device - AR91.60-P-0611-04A

Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect the power supply. 

Models 124, 129 up to 30.6.93, 140, 202 up to 30.6.93 

Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13). 

Models 163, 168, 170, 202, 203, 208, 209, 210, 215, 220, 230, 240, 414, 461, 463 

All models 

For testing arrangement, turn rotary switch of deployment device to position Cable set plug, no. up to 6/93 Cable set plug, no. as of 7/93 Test scope Press: Keys Specified value: LED Possible causes for deviation from specified value
1     Internal battery test BATTERY Press Deployment device not connected BATTERY ON Replace any battery set for ignition device: 2 Baby cells
          Green malfunction indicator lamp ON (2 x 1.5 V)
1 3+4 10+11 Actuation of driver side squib Press both pushbuttons
  1. Before actuation
Trigger circuit is defective
          BATTERY ON  
2 1+2
3+4
1+2
3+4
Deployment of emergency tensioning retractor squib, left seat Deployment of emergency tensioning retractor squib, right seat Press both pushbuttons Deployment makes a bang Trigger circuit is defective
3 5+6 13+14 Ignition Front passenger squib Press both pushbuttons
  1. 2. After deployment
Trigger circuit is defective
          BATTERY ON  
          Green malfunction indicator lamp ON