Deployment of airbag units when no deployment device is present - AR91.60-P-0611-05A
MODELS 163, 170, 202 as of 1.7.93, 208, 210,414,463
Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect the power supply.
MODEL 202 up to 30.6.93
Store airbag unit with expulsion area on top, do not subject to temperatures above 100 °C. When working on these units, disconnect power supply and unplug the SRS test connector (X11/13).
Models 163, 168, 170, 202, 203, 208, 210, 215,220,414,463
All models
Application of shop-made ignition cables
- Make up ignition cable of min. 10 m length with pressure switch.
- Plug the 2-pin plug connector into the corresponding airbag unit.
- Connect ignition cables to the battery.
- Press both pressure switches simultaneously.
- For airbag units with 2 squibs, both must be deployed. To do this, repeat steps 2 through 4 after plugging the ignition cable into the second squib.
Keep a distance of 10 meters for safety.