Test 35: Right Front Power Window Motor
Using Adapter (140 589 12 63 00), connect Breakout Box (129 589 00 21 00) to combination control module. See Figure. Turn ignition switch to OFF position. Disconnect combination control module connector "A". See Figure. Connect fused jumper wires between terminals No. 11 and 44 and terminals No. 5 and 10 at breakout box. Right front power window should open. If right front window does not open, check wiring. See WIRING DIAGRAMS . If wiring is okay, replace right front power window motor.