Shift Linkage
Before adjusting shift linkage, make sure neutral safety switch is properly adjusted. See NEUTRAL SAFETY SWITCH . To adjust shift linkage, disconnect control rod from gear selector lever. Place transmission lever in "N" (Neutral) position. Loosen lock nut at end of control rod. Adjust rod length so clearance is .04" (1 mm) between gear selector lever and "N" stop on gate plate. Connect control rod, and secure and tighten lock nut. See Fig 1 .