Modulating Pressure Adjustment
- Remove rubber cap on vacuum control unit. Pull locking plate out of locking slots to permit rotation.
- Adjusting screw in vacuum modulator can now be adjusted by means of locking plate. One turn of adjusting screw results in a pressure change of 6 psi (.4 kg/cm2 ).
- After turning adjusting screw, push locking plate back into locking slots. Put robber cap back on vacuum control unit. Measure modulating pressure once again. Plug-on vacuum line and screw to holder.
NOTE:
Working pressure is not adjustable. Pressure is automatically established with correctly adjusted modulating pressure.