DTC U010E-00: Communication Error With Dosing Control Unit
U010E:00 (BCM) DETECTION CONDITION AND POSSIBLE CAUSE
| System malfunction location | Communication error with dosing control unit | |
|---|---|---|
| Detection condition |
|
|
| Fail-safe |
|
|
| Vehicle status when DTCs are output | • Not applicable | |
| Repeatability verification procedure | 1. Clear the DTC recorded in the memory. (See CLEARING DTC .) | |
| Inspection/action procedure | • Proceed with the inspection/action in the order from Step 1 below. • After part repair or replacement, perform the repeatability verification procedure and perform a DTC inspection. (See DTC INSPECTION .) If the DTC inspection indicates the same DTC again, go to the next step. 1. Perform the malfunction diagnosis according to the troubleshooting procedure for the multiplex communication system. |
|
| Purpose/reason (possible cause) | Malfunction in the CAN communication line between the dosing control unit and the body control module (BCM) | |
| Referred to service information item | MALFUNCTION DIAGNOSIS FLOW [CONTROLLER AREA NETWORK (CAN)] | |
| System wiring diagram |
|
|