LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2023 >> MX-5 Miata Club >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> On-Board Diagnostic - Start Stop Unit >> DTC B124C-56: Turn Switch Internal Circuit Malfunction [Start Stop Unit] >> Notes

DTC B124C-56: Turn Switch Internal Circuit Malfunction [Start Stop Unit]: Notes

DTC B124C:56 (START STOP UNIT) DETECTION CONDITION AND POSSIBLE CAUSE

Description Turn switch internal circuit malfunction
Detection condition
  • Start stop unit detects that the turn switch LH and RH are turned on simultaneously for 5 s or more.
Fail-safe Not applicable
Possible cause
  • Start stop unit configuration error
  • The installations of the light switch and the wiper and washer switch are reversed.
  • Turn switch malfunction
  • Start stop unit malfunction
System wiring diagram Not applicable