| B115E:54 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) aiming not completed |
x |
- |
C, D |
x |
(See DTC B115E:54: [FORWARD SENSING CAMERA (FSC)] .) |
| B115E:76 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) axis deviation |
x |
- |
C, D |
x |
(See DTC B115E:76: [FORWARD SENSING CAMERA (FSC)] .) |
| B115E:78 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) axis deviation (detected during mid-drive aiming) |
x |
- |
C, D |
x |
(See DTC B115E:78: [FORWARD SENSING CAMERA (FSC)] .) |
| B115E:9A |
Illuminated |
Illuminated |
Forward sensing camera (FSC) mid-drive aiming time-out |
x |
- |
C, D |
x |
(See DTC B115E:9A: [FORWARD SENSING CAMERA (FSC)] .) |
| B13A6:11 |
Illuminated |
- |
LDWS switch circuit malfunction |
x |
- |
C, D |
x |
(See DTC B13A6:11: [FORWARD SENSING CAMERA (FSC)] .) |
| C0063:28 |
Illuminated |
Illuminated |
Yaw rate sensor poor accuracy |
x |
- |
C, D |
x |
(See DTC C0063:28: [FORWARD SENSING CAMERA (FSC)] .) |
| C1001:92 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) poor field of view |
x |
- |
C, D |
x |
(See DTC C1001:92: [FORWARD SENSING CAMERA (FSC)] .) |
| C1001:97 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) poor visibility |
x |
- |
C, D |
x |
(See DTC C1001:97: [FORWARD SENSING CAMERA (FSC)] .) |
| U0001:88 |
Illuminated |
Illuminated |
Module communication error (HS-CAN) |
x |
- |
C, D |
x |
(See DTC U0001:88/U0100:00/U0121:00/U0131:00/U0140:00/U0151:00/U0155:00/U0156:00/U0214:00: [FORWARD SENSING CAMERA (FSC)] .) |
| U0100:00 |
Illuminated |
Illuminated |
Communication error with PCM |
x |
- |
C, D |
x |
| U0121:00 |
Illuminated |
Illuminated |
Communication error with DSC HU/CM |
x |
- |
C, D |
x |
| U0131:00 |
Illuminated |
- |
Communication error with electric power steering (EPS) control module |
x |
- |
C, D |
x |
| U0140:00 |
Illuminated |
Illuminated |
Communication error with body control module (BCM) |
x |
- |
C, D |
x |
| U0151:00 |
Illuminated |
Illuminated |
Communication error with SAS control module |
x |
- |
C, D |
x |
| U0155:00 |
Illuminated |
Illuminated |
Communication error with instrument cluster |
x |
- |
C, D |
x |
| U0156:00 |
- |
- |
Communication error with connectivity master unit (CMU) |
- |
- |
C, D |
x |
| U0214:00 |
Illuminated |
Illuminated |
Communication error with start stop unit |
x |
- |
C, D |
x |
| U0401:68 |
Illuminated |
Illuminated |
Error signal received from PCM |
x |
- |
C, D |
x |
(See DTC U0401:68: [FORWARD SENSING CAMERA (FSC)] .) |
| U0415:68 |
Illuminated |
Illuminated |
Error signal received from DSC HU/CM |
x |
- |
C, D |
x |
(See DTC U0415:68: [FORWARD SENSING CAMERA (FSC)] .) |
| U0420:68 |
Illuminated |
- |
Error signal received from electric power steering (EPS) control module |
x |
- |
C, D |
x |
(See DTC U0420:68: [FORWARD SENSING CAMERA (FSC)] .) |
| U0423:68 |
Illuminated |
- |
Error signal received from instrument cluster |
x |
- |
C, D |
x |
(See DTC U0423:68: [FORWARD SENSING CAMERA (FSC)] .) |
| U0452:4A |
Illuminated |
Illuminated |
SAS control module serial number mismatch |
x |
- |
C, D |
x |
(See DTC U0452:4A: [FORWARD SENSING CAMERA (FSC)] .) |
| U0515:68 |
Illuminated |
Illuminated |
Error signal received from start stop unit |
x |
- |
C, D |
x |
(See DTC U0515:68: [FORWARD SENSING CAMERA (FSC)] .) |
| U2100:00 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) configuration error |
x |
- |
C, D |
x |
(See DTC U2100:00: [FORWARD SENSING CAMERA (FSC)] .) |
| U2300:51 |
Illuminated |
Illuminated |
Vehicle identification number (VIN) mismatch |
x |
- |
C, D |
x |
(See DTC U2300:51: [FORWARD SENSING CAMERA (FSC)] .) |
| U2300:54 |
Illuminated |
Illuminated |
Configuration data not received from instrument cluster |
x |
- |
C, D |
x |
(See DTC U2300:54: [FORWARD SENSING CAMERA (FSC)] .) |
| U2300:55 |
Illuminated |
Illuminated |
Instrument cluster configuration not implemented |
x |
- |
C, D |
x |
(See DTC U2300:55: [FORWARD SENSING CAMERA (FSC)] .) |
| U2300:56 |
Illuminated |
Illuminated |
Configuration data unmatched with instrument cluster |
x |
- |
C, D |
x |
(See DTC U2300:56: [FORWARD SENSING CAMERA (FSC)] .) |
| U2300:64 |
Illuminated |
Illuminated |
Instrument cluster configuration error |
x |
- |
C, D |
x |
(See DTC U2300:64: [FORWARD SENSING CAMERA (FSC)] .) |
| U3000:04 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) internal malfunction |
x |
- |
C, D |
x |
(See DTC U3000:04/U3000:42/U3000:49: [FORWARD SENSING CAMERA (FSC)] .) |
| U3000:42 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) internal malfunction |
x |
- |
C, D |
x |
| U3000:49 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) internal malfunction |
x |
- |
C, D |
x |
| U3000:98 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) stops functioning due to temporary high temperature |
x |
- |
C, D |
x |
(See DTC U3000:98: [FORWARD SENSING CAMERA (FSC)] .) |
| U3003:16 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) low power supply voltage input |
x |
- |
C, D |
x |
(See DTC U3003:16: [FORWARD SENSING CAMERA (FSC)] .) |
| U3003:17 |
Illuminated |
Illuminated |
Forward sensing camera (FSC) high power supply voltage input |
x |
- |
C, D |
x |
(See DTC U3003:17: [FORWARD SENSING CAMERA (FSC)] .) |