Home >> Mazda >> 2023 >> CX-50 S Select >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Negative Battery Terminal Disconnection/Connection >> Negative Battery Terminal Connection >> Vehicle with i-stop

Vehicle with i-stop

CAUTION:
  • Connect the negative battery terminal before connecting the current sensor connector. If the current sensor connector is connected first, the PCM may mistakenly recognize a signal from the current sensor and learn the battery condition incorrectly.
  • Verifying the tightness while holding the current sensor may apply excessive force to the terminal and the terminal could loosen, causing poor engine starting. When verifying the tightness of the negative battery terminal, only hold the terminal area, not the current sensor.
    G13714162Courtesy of MAZDA MOTORS CORP.
  • When tightening the negative battery terminal, tighten it to the specified torque. If it is not tightened to the specified torque, the battery charging/discharging may be affected. (See BATTERY REMOVAL/INSTALLATION (VIN Y) .)
  1. Perform battery condition initial setting (i-stop setting). (See BATTERY CONDITION INITIALIZATION SETTING (I-STOP SETTING) .)
NOTE:
  • Connection of the negative battery terminal and the current sensor connector will be done in the battery condition initial setting (i-stop setting) procedure.