| 1 |
INSPECT LIFTGATE LATCH SWITCH CONNECTOR CONDITION
- Switch the ignition off.
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION
.)
- Disconnect the liftgate latch switch connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
|
Yes |
Go to the next step. |
| No |
Repair or replace the connector, then go to Step 11. |
| 2 |
INSPECT LIFTGATE LATCH SWITCH GROUND CIRCUIT FOR OPEN CIRCUIT
- Verify that the liftgate latch switch connector is disconnected.
- Inspect for continuity between liftgate latch switch terminal A (wiring harness-side) and body ground.
- Is there continuity?
|
Yes |
Go to the next step. |
| No |
Refer to the wiring diagram and verify whether or not there is a common connector between liftgate latch switch terminal A and body ground. If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Go to Step 11. |
| 3 |
INSPECT LIFTGATE LATCH SWITCH
|
Yes |
Go to the next step. |
| No |
Replace the liftgate latch switch, then go to Step 11. (See LIFTGATE LATCH AND LOCK ACTUATOR REMOVAL/INSTALLATION
.) |
| 4 |
INSPECT POWER LIFTGATE (PLG) LATCH SWITCH CONNECTOR CONDITION
- Disconnect the power liftgate (PLG) latch switch connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
|
Yes |
Go to the next step. |
| No |
Repair or replace the connector, then go to Step 11. |
| 5 |
INSPECT POWER LIFTGATE (PLG) LATCH SWITCH GROUND CIRCUIT FOR OPEN CIRCUIT
- Verify that the power liftgate (PLG) latch switch connector is disconnected.
- Inspect for continuity between power liftgate (PLG) latch switch terminal C (wiring harness-side) and body ground.
- Is there continuity?
|
Yes |
Go to the next step. |
| No |
Refer to the wiring diagram and verify whether or not there is a common connector between power liftgate (PLG) latch switch terminal C and body ground. If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Go to Step 11. |
| 6 |
INSPECT POWER LIFTGATE (PLG) CONTROL MODULE CONNECTOR CONDITION
- Disconnect the power liftgate (PLG) control module connector.
- Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
- Is the connector normal?
|
Yes |
Go to the next step. |
| No |
Repair or replace the connector, then go to Step 11. |
| 7 |
INSPECT LATCH SWITCH CIRCUIT FOR SHORT TO GROUND
- Verify that the liftgate latch switch, power liftgate (PLG) latch switch and power liftgate (PLG) control module connectors are disconnected.
- Inspect for continuity between the following terminals (wiring harness-side) and body ground:
- Liftgate latch switch terminal B
- Power liftgate (PLG) latch switch terminal E
- Power liftgate (PLG) latch switch terminal B
- Power liftgate (PLG) latch switch terminal D
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
- Liftgate latch switch terminal B-Power liftgate (PLG) control module terminal 1S
- Power liftgate (PLG) latch switch terminal E-Power liftgate (PLG) control module terminal 1T
- Power liftgate (PLG) latch switch terminal B-Power liftgate (PLG) control module terminal 1Q
- Power liftgate (PLG) latch switch terminal D-Power liftgate (PLG) control module terminal 1O
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has a short to ground.
Go to Step 11. |
| No |
Go to the next step. |
| 8 |
INSPECT LATCH SWITCH CIRCUIT FOR SHORT TO POWER SUPPLY
- Verify that the liftgate latch switch, power liftgate (PLG) latch switch and power liftgate (PLG) control module connectors are disconnected.
- Connect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION
.)
- Switch the ignition ON (engine off or on).
- Measure the voltage at the following terminals (wiring harness-side):
- Liftgate latch switch terminal B
- Power liftgate (PLG) latch switch terminal E
- Power liftgate (PLG) latch switch terminal B
- Power liftgate (PLG) latch switch terminal D
|
Yes |
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
- Liftgate latch switch terminal B-Power liftgate (PLG) control module terminal 1S
- Power liftgate (PLG) latch switch terminal E-Power liftgate (PLG) control module terminal 1T
- Power liftgate (PLG) latch switch terminal B-Power liftgate (PLG) control module terminal 1Q
- Power liftgate (PLG) latch switch terminal D-Power liftgate (PLG) control module terminal 1O
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has a short to power supply.
Go to Step 11. |
| No |
Go to the next step. |
| 9 |
INSPECT LATCH SWITCH CIRCUIT FOR OPEN CIRCUIT
- Switch the ignition off.
- Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION
.)
- Verify that the liftgate latch switch, power liftgate (PLG) latch switch and power liftgate (PLG) control module connectors are disconnected.
- Inspect for continuity between the following terminals (wiring harness-side):
- Liftgate latch switch terminal B-Power liftgate (PLG) control module terminal 1S
- Power liftgate (PLG) latch switch terminal E-Power liftgate (PLG) control module terminal 1T
- Power liftgate (PLG) latch switch terminal B-Power liftgate (PLG) control module terminal 1Q
- Power liftgate (PLG) latch switch terminal D-Power liftgate (PLG) control module terminal 1O
|
Yes |
Go to the next step. |
| No |
Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
- Liftgate latch switch terminal B-Power liftgate (PLG) control module terminal 1S
- Power liftgate (PLG) latch switch terminal E-Power liftgate (PLG) control module terminal 1T
- Power liftgate (PLG) latch switch terminal B-Power liftgate (PLG) control module terminal 1Q
- Power liftgate (PLG) latch switch terminal D-Power liftgate (PLG) control module terminal 1O
If there is a common connector:
- Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.
- Repair or replace the malfunctioning part.
If there is no common connector:
- Repair or replace the wiring harness which has an open circuit.
Go to Step 11. |
| 10 |
INSPECT POWER LIFTGATE (PLG) LATCH SWITCH
|
Yes |
Go to the next step. |
| No |
Replace the power liftgate (PLG) latch switch, then go to the next step. (See LIFTGATE LATCH AND LOCK ACTUATOR REMOVAL/INSTALLATION
.) |
| 11 |
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes |
Repeat the inspection from Step 1.
Go to the next step. |
| No |
Go to the next step. |
| 12 |
VERIFY IF OTHER DTCs DISPLAYED
- Are any other DTCs displayed?
|
Yes |
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [POWER LIFTGATE (PLG) CONTROL MODULE] .) |
| No |
DTC troubleshooting completed. |