Blower Fan Controller Removal/Installation

  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Remove the following parts:
    1. Glove compartment (See GLOVE COMPARTMENT REMOVAL/INSTALLATION .)
    2. Dashboard under cover (See DASHBOARD UNDER COVER REMOVAL/INSTALLATION .)
  3. Disconnect the blower fan controller connector.
    G11430224Courtesy of MAZDA MOTORS CORP.
  4. Rotate the blower fan controller (2) while pressing the tab (1).
    G11430225Courtesy of MAZDA MOTORS CORP.
  5. Remove the blower fan controller.
    G11430226Courtesy of MAZDA MOTORS CORP.
  6. Install in the reverse order of removal.