DTC U2300-55: Instrument Cluster Configuration Not Implemented (Blind Spot Monitoring System): Notes
DTC U2300:55 (BLIND SPOT MONITORING SYSTEM) DETECTION CONDITION AND POSSIBLE CAUSE
| Description |
Instrument cluster configuration not implemented |
| Detection condition |
- Blind spot monitoring (BSM) control module (LH) received a signal which indicates the instrument cluster configuration is not performed with the ignition switched ON (engine off or on).
|
| Fail-safe |
- Blind spot monitoring (BSM) system is stopped.
|
| Possible cause |
NOTE:
- To correctly write the configuration data sent from the instrument cluster to the Blind spot monitoring (BSM) control module (LH) to the blind spot monitoring (BSM) control module (LH), 30 s or more need to have elapsed since the ignition was switched ON (engine off or on).
- Instrument cluster configuration is not completed.
- Blind spot monitoring (BSM) control module (LH) malfunction
|
| System wiring diagram |
Not applicable |