DTC B118C-11: Blind Spot Monitoring (BSM) Warning Light (LH) Circuit Malfunction [Blind Spot Monitoring (BSM) Control Module]: Notes
DTC B118C:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE] DETECTION CONDITION AND POSSIBLE CAUSE
| Description |
Blind spot monitoring (BSM) warning light (LH) circuit malfunction |
| Detection condition |
- Blind spot monitoring (BSM) control module (LH) performs measurement at 0.01 s intervals and a short to ground in the blind spot monitoring (BSM) warning light (LH) circuit is detected 48 times continuously.
|
| Fail-safe |
- Blind spot monitoring (BSM) system is stopped.
|
| Possible cause |
- Blind spot monitoring (BSM) warning light (LH) connector or terminal malfunction
- Blind spot monitoring (BSM) control module (LH) connector or terminal malfunction
- Short to ground in wiring harness between blind spot monitoring (BSM) control module (LH) terminal G and blind spot monitoring (BSM) warning light (LH) terminal D
- Blind spot monitoring (BSM) warning light (LH) malfunction
- Blind spot monitoring (BSM) control module (LH) malfunction
|