LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2020 >> CX-30 Select, AWD >> Repair and Diagnosis >> Electrical >> Body Electrical >> Power Systems >> Backup Power Supply Inspection

Backup Power Supply Inspection

  1. Disconnect the negative battery terminal.
  2. Remove the backup power supply. (See BACKUP POWER SUPPLY REMOVAL/INSTALLATION (US) .)
  3. Connect the backup power supply connector.
  4. Connect the negative battery terminal.
  5. Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).
    • If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) and related wiring harnesses.

Terminal Voltage Table (Reference) 

G13561114Courtesy of MAZDA MOTORS CORP.
Terminal Signal name Connected to Test condition Voltage (V) Inspection item
A Power supply Electrical supply unit (ESU) Under any condition B+
  • Electrical supply unit (ESU)
  • Related wiring harness
B Power supply Electrical supply unit (ESU) Under any condition B+
  • Electrical supply unit (ESU)
  • Related wiring harness
C Power supply (IG1) F48 7.5A fuse Ignition switched ON (engine off or on) B+
  • F48 7.5A fuse
  • Related wiring harness
Ignition switched OFF (LOCK) 1.0 or less
D 78 - - - -
E - - - - -
F - - - - -
G - - - - -
H - - - - -
I GND Body ground Under any condition Approx. 0
  • GND point
  • Related wiring harness
J Power supply Electrical supply unit (ESU) Under any condition B+
  • Electrical supply unit (ESU)
  • Related wiring harness