Diagnostic Procedure
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | VERIFY OTHER RETRACTABLE FASTBACK CONTROL MODULE DTCs
|
Yes | Replace the retractable fastback control module, then go to Step 4. (See RETRACTABLE FASTBACK CONTROL MODULE REMOVAL/INSTALLATION ). |
| No | Go to the next step. | ||
| 2 | VERIFY INSTRUMENT CLUSTER DTCs
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [INSTRUMENT CLUSTER] ). |
| No | Go to the next step. | ||
| 3 | INSTRUMENT CLUSTER CONFIGURATION DATA
|
Yes | Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step. (See INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA) ). |
| No | Go to Step 5. | ||
| 4 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
Go to the next step. |
| No | Go to the next step. | ||
| 5 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [RETRACTABLE FASTBACK CONTROL MODULE] ). |
| No | DTC troubleshooting completed. | ||