LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2017 >> CX-9 Signature >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generator Inspection >> Generator Internal Parts >> Rectifier (Using an analog circuit tester)

Rectifier (Using an analog circuit tester)

  1. Inspect for continuity of the diodes using an analog circuit tester.
Fig 1: Inspecting For Continuity Of Diodes
G11436031Courtesy of MAZDA MOTORS CORP.

Specification 

Negative Positive Continuity
E P1, P2, P3, P4, P5, P6 Yes
B No
P1, P2, P3, P4, P5, P6 E No
B Yes