Power Window SUBSWITCH Inspection: Notes
- Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION
.)
- Remove the power window subswitch. (See POWER WINDOW SUBSWITCH REMOVAL/INSTALLATION .)
- Connect the power window subswitch connector.
- Connect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION
.)
- Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).
- If the voltage is not as specified in the terminal voltage table (reference), inspect the parts under Inspection item(s) and related wiring harnesses.
- If the system does not work normally even though the inspection items are normal, replace the power window subswitch.