| DETECTION CONDITION |
- Vehicle condition: TCM communication normal while engine rotates in warm-up condition
- Status: Detects ATF temperature of 200 °C {392 °F} or more
- Period: Confirmed 6 times in 10 s or more
|
| FAIL-SAFE FUNCTION |
- Performs control with the ATF temperature of 80 °C {176 °F}
.
- Inhibits learning control.
- Inhibits the neutral control.
- Inhibits slip control.
- Inhibits the slope control.
- Inhibits AAS mode.
- Inhibits 5GR and 6GR.
- Inhibits direct mode.
- Inhibits the torque increase request.
|
| POSSIBLE CAUSE |
- TFT sensor malfunction
- TCM connector or terminal malfunction
- Short to ground in wiring harness between TFT sensor and TCM terminal 2J
- Short to ground in wiring harness between TFT sensor and TCM terminal 2M
- TCM malfunction
|
|
|