| Possible Causes |
- Power window system initial setting not completed
- Power window sub switch malfunction
- Power window motor (RH) malfunction
- Open circuit in wiring harness between the following terminals:
- Power window sub switch terminal D and power window motor (RH) terminal B
- Power window sub switch terminal L and power window motor (RH) terminal H
- Power window sub switch terminal E and power window motor (RH) terminal F
- Power window sub switch terminal J and power window motor (RH) terminal D
- Short to ground in wiring harness between the following terminals:
- Power window sub switch terminal D and power window motor (RH) terminal B
- Power window sub switch terminal E and power window motor (RH) terminal F
- Power window sub switch terminal J and power window motor (RH) terminal D
- Short to power supply in wiring harness between the following terminals:
- Power window sub switch terminal D and power window motor (RH) terminal B
- Power window sub switch terminal E and power window motor (RH) terminal F
- Connector poor contact or terminal damage
|