LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2015 >> 3 SV, Automatic Trans >> Repair and Diagnosis >> Electrical >> Charging Systems >> I-ELOOP Technical Data >> i-ELOOP TECHNICAL DATA

i-ELOOP TECHNICAL DATA

Item Specification
Generator standard voltage [IG-ON] Terminal 1A: Capacitor voltage
Terminal 2A: Approx. 1.0 V
Terminal 2B: Approx. 1.0 V
Terminal 2C: B+
Generator standard voltage [Idle, 20 °C {68 °F}] Terminal 1A: Capacitor voltage
Terminal 2A, 2B: Turn the electrical loads (such as headlights, blower motor, rear window defroster, brake lights) on and verify that the voltage reading increases.
Terminal 2C: B+
Generator rotor resistance (between slip rings) [20 °C {68 °F}] 1.8-2.1 ohms
Generator brush length Standard: 22.5 mm {0.886 in}
Minimum: 5.0 mm {0.20 in}
Generator brush spring force Standard: 4.1-5.3 N {0.42-0.54 kgf, 1.0-1.1 lbf}
Minimum: 1.7 N {0.17 kgf, 0.38 lbf}
GENERATOR GENERATED CURRENT MAXIMUM VALUE DESCRIPTION

Engine speed (rpm) Terminal 1A voltage (V) Generator output current (A)
1, 000 15 130
2, 000 15 150